VERIFIER SETUP GUIDE Use this Setup Guide to install and set up your OLV (online verifier) with the Monarch 9864 printer. The verifier scans and ra
Menu Parameter Description OLV PARAMETER Symbol Contrast Default: -1 No checking 0-100 The value must be higher than or equal to the set limit. OL
Troubleshooting the Verifier You may receive the following error messages when using the verifier. Status Number Description 4100 NO OLV data The ve
Visit www.monarch.com for sales, service, supplies, information, and telephone numbers for our International locations. TOLL FREE: 1-80
Installing the Verifier To install the verifier: 1. Remove the knife module if the printer has one installed. 2. Use a 4mm hex wrench to attach the
7. Slide the verifier onto the mounting arm as shown. The flat edge of the shaft faces the set screw. Tighten the set screw. Set screw Knob 8. Use
Connecting the Verifier Connect the verifier's DB15 I/O port to the verifier's power supply. Connect the verifier's DB9 COMM port to ei
Configuring the Verifier Certain parameters must be set at the printer to configure the verifier. You only need to make these settings once since the
Online Verifier Communication Settings You can use Com1 or Com2. The printer must match the verifier's communication settings: 115200 Baud, 8 d
14. Press Cut or Feed to display Data synch. and press Online. Data synch. XON/XOFF 15. Press Cut or Feed to display RTS/CTS (hardware sync.) and
8. Press Online. Cancel Printing Enabled Press Cut or Feed to display the option you need and press Online. When Cancel printing is "Enabled,&
Online Verifier Parameter List For normal operation, set all parameters to their default values except ANSI Symbolgrade. Set ANSI Symbolgrade to the